Three Major Application Scenarios
Full Coverage of Energy Optimization Scenarios

Industrial & Parks
Smart Factory • Industrial Parks
Typical Application Cases
Core Technical Features
Your building HVAC system may be wasting more than 40% of energy!
An intelligent, efficient, and convenient technology is urgently needed to enhance energy-saving retrofits of existing buildings
Soaring Energy Costs
HVAC energy consumption accounts for 30-40% of operating costs, your electricity bills keep rising year after year
Equipment Operating Independently
Air conditioners, pumps, and cooling towers operate without coordination, causing serious energy waste
Reliance on Manual Experience
Relying on experienced technicians for adjustments, scrambling when weather changes, unable to achieve precise control
High Risk of Traditional Retrofits
Large-scale engineering retrofits take long time, require high investment, and affect normal operations during construction
Core Technology — DeepEnergy AI
Global Optimization Based on Model-Free Reinforcement Learning
DeepEnergy is not just automation—it's an intelligent agent with a "brain"
Technical Core: PPO Algorithm
Proximal Policy Optimization
We upgrade traditional control algorithms to the more advanced PPO (Proximal Policy Optimization) model-free reinforcement learning algorithm.
Automatically Find Optimal Solutions
Treating all equipment as a whole, AI automatically finds the most energy-efficient solution from tens of thousands of operating combinations
Ensure Stable Operation
Smooth and gradual adjustment process, ensuring system safety and stability, avoiding frequent equipment start-stop
No Complex Retrofits Needed
Directly learns from on-site data, low requirements for sensor accuracy, adapts to various old equipment
Changes After AI Intervention
Dynamically adjusts equipment frequency and quantity based on real-time load, weather, and peak-valley electricity prices
Temperature is more stable under AI control, with predictive adjustments to improve comfort
Deployment Solution — Edge Computing, Fast Online
No equipment replacement, no downtime, deployment completed in ~28 days
Edge Computing for Fast Deployment
Edge Computing Deployment
AI Box deployed directly on-site, only requires network cable connection to host computer or PLC
Minimal Construction
No need to replace large mechanical and electrical equipment, does not affect daily building operations
Rapid Launch
From hardware installation, data integration to algorithm launch, results can be seen in as fast as 28 days
Real-Time Feedback
On-site data reading → Edge computing processing → Optimization command delivery → Real-time feedback
Data Flow: On-site data reading → Edge computing processing → Issue optimization instructions → Real-time feedback
Safety Assurance — Multiple "Locks" for All Your Concerns
Safety boundaries + heartbeat mechanism, safer than the original system
We understand that safety is the bottom line of facility management. DeepEnergy has three layers of protection
Safe Boundary
Algorithm has built-in strict thresholds (such as water temperature, frequency limits). Any AI decision must be within safe range, absolutely no over-limit commands
Heartbeat Detection
Server continuously sends heartbeat signals. Once signal interruption or equipment failure occurs, system automatically switches back to original PID control or manual mode in milliseconds
Cooling Capacity Redundancy
Algorithm automatically calculates cooling capacity redundancy, reserving safety margin to handle sudden load increases
Data Security
Core data runs locally, no mandatory public network upload, supports firewall protection
Benchmark Cases — Real and Visible Energy Savings
Energy-saving evidence from commercial complexes and top-tier hospitals
Proven Energy Savings in Real Projects
G60 Innovation Corridor
Commercial Complex / Park
Project Overview
Total area exceeds 1 million square meters, consisting of 23 high-rise buildings, equipped with ice storage system
Solution
Key Data
Xiamen Hong'ai Hospital
Medical & Healthcare
Project Overview
Large modern tertiary general hospital with extremely high requirements for environmental temperature and humidity control and system safety
Solution
Key Data
Business Cooperation Models
Flexible cooperation, share green benefits
Two flexible payment options to match your budget planning
EMC Model
Energy Management Contract
💡 Suitable for customers who want zero investment and shared revenue
EPC Model
Engineering Procurement Construction
💡 Suitable for customers who want complete ownership and exclusive benefits
FAQ
Frequently Asked Questions
Q:Do I need to install a large number of sensors?
A: No. DeepEnergy does not require complex modeling and has low dependency on sensors. It typically utilizes existing BA system data (such as main pipe temperature, power, etc.), no large-scale hardware retrofit needed.
Q:What happens if AI fails? Will it affect air conditioning?
A: No. The system has a "hot standby" mechanism. When AI fails, it automatically switches back seamlessly to the original control mode, like a "plug-in" for the system - removing the plug-in, the system operates normally.
Q:How is energy-saving rate calculated?
A: We typically use A/B testing (alternating operation) method. That is "AI control one day, original mode control one day", comparing energy consumption under similar weather and load conditions, data is open and transparent.
Q:What is the difference between DeepEnergy and traditional BMS systems?
A: Traditional BMS controls according to fixed rules (such as PID), DeepEnergy automatically finds optimal solutions through AI learning. BMS tells the system "how to do it", DeepEnergy finds the "optimal solution" through learning.
Q:What does the 28-day deployment cycle include?
A: Includes: on-site survey and data integration (5-7 days), AI Box hardware installation (3-5 days), AI learning and optimization (10-14 days), trial operation and verification (5-7 days). Specific cycle depends on project scale.
Q:What advantages does the PPO algorithm have over traditional RL?
A: PPO technology is more stable and safer when updating optimization strategies, avoiding sudden system fluctuations. It is particularly suitable for scenarios with high stability requirements such as HVAC control.